1 / 5
| Parameter | Details |
|---|---|
| Model | HT-BCT10A30V |
| Power | AC200-240V 50/60HZ (If you need 110V, please inform us in advance) |
| Charging range | 1-30V / 0.5-10A Adj |
| Discharge range | 1-30V / 0.5-10A Adj |
| Work step | Charge / Discharge / Rest time / Cycle 9999 times |
| Communication | USB, WIN XP or above systems, Chinese or English |
| Auxiliary functions | Voltage balancing (CV Discharge) |
| Protective function | Battery overvoltage / Battery reverse connection / Battery disconnection / Fan not running |
| Calibration equipment | V: Fluke 8845A, A: Gwinstek PCS-1000I |
| Accuracy | V±0.1%, A±0.1% (Accuracy guarantee is within one year from purchase date) |
| Cooling | Cooling fans open at 40°C, protected at 83°C (please check and maintain the fans regularly) |
| Working environment | 0-40°C, air circulation, do not allow heat to accumulate around the machine |
| Warning | It is forbidden to test batteries over 30V |
| Size and weight | Product Size 167*165*240mm, Weight 2.6Kg |












With stable performance, cost-effective products, and high-quality services, our products have gained an excellent reputation and receive positive evaluations in France, Germany, Russia, the United States, South Korea, and other countries globally.