1 / 5
| Model Specification | ATC820-L-L2 |
| Machine Type Classification | Two channel leak tester |
| Measurement Method | High - Precision Differential Pressure Measurement Method |
| Pressure Regulation Method | Selectable between High - Precision Mechanical Pressure Regulation and Electronic Pressure Regulation |
| Pressure Sensor (Pressure Display) |
Test Pressure: 2 - 150 KPa Pressure Units: kPa, mmH2O, Torr, PSI Pressure Resolution: 0.1 KPa Display Accuracy: 0.5% F.S |
| Differential Pressure Sensor (Leakage Measurement) |
Units: Pa, Pa/s, sccm (cc/min). Differential Pressure Range: ±2500Pa. Differential Pressure Resolution: 0.1Pa. Test Accuracy: 0.25%F.S of rdg ±1Pa. Typical Error: ≤±2Pa within 50Pa |
| Leakage Rate Measurement | Equivalent Volume Range: 0.1 - 999.9mL. Leakage Rate Test Range: 0.001 -999sccm. Leakage Rate Resolution: 0.001sccm |
| Time Setting | Delay Time: 0.1 - 999.9 sec Inflation Time: 0.1 - 999.9 sec Equilibration Time: 0.1 - 999.9 sec Detection Time: 0.1 - 999.9 sec Exhaust Time: 0.1 - 999.9 sec |
| Screen Size | 7 - inch Color Touch Screen |
| External Control I/O | 5 - way Input and 6 - way Output |
| External Control Connector | DP37 Connector, USB, RS485, RJ45 |
| Data Transfer | U Disk Data Transfer Function |
| Communication Function | RS485 Communication |
| Alarm Function | Pass/Fail Alarm Output |
| Auxiliary Function | Bubble Leak Detection Function |
| Power Input | AC220V/50Hz |
| Power | Approximately 40W |
| Air Source Used | ≥0.4MPa Stable and Dry Compressed Air |
| Test Port | Φ4, Φ6, Test Gas Tubes Are Selectable (Default Φ4 Pressure - Resistant and Constant - Temperature Gas Tube) |
| Operating Environment | 5~30°C/20~80%RH (Non - Condensing) |
| Product Dimensions | 300×225×450mm(W*H*D) |